Recessed Floor Fan Coils FCH
High heating and cooling capacity, allowing use as primary heating devices even in low energy efficiency buildings
Extremely low noise level, suitable for rooms with strict acoustic requirements
Integrated condensate collection trays, ensuring operation below the dew point
2 and 4 pipe models:
– 4 pipe system – maximum heating and cooling flexibility
– 2 pipe system – maximum power
Efficient operation with low-temperature heat sources, such as heat pumps and condensing boilers
Low thermal inertia – heat (or cool) is supplied only as needed, significantly reducing energy consumption and avoiding overheating of rooms
EC fans – quiet operation and maximum efficiency, ensuring up to 4× greater convection efficiency
Robust stainless steel casings, designed for pedestrian loads and capable of supporting the weight of several adults
Double-sided aesthetic grilles made of aluminum or oak wood
Designed and manufactured in Lithuania
The FCH series high-power floor fan coils are designed for efficient room heating and cooling, ensuring comfort even in low energy efficiency buildings. Due to their high heating and cooling capacity, these units can be used as primary heating and cooling devices.
They feature an extremely low noise level, making them suitable for spaces with strict acoustic requirements, such as living areas, hotel rooms, or offices. Integrated condensate collection trays allow the units to operate reliably below the dew point, ensuring a stable cooling mode.
The FCH series is offered with 2 or 4 pipe connections. The 4 pipe system provides maximum heating and cooling flexibility, allowing both modes to be controlled independently, while the 2 pipe system focuses on maximum instantaneous power.
The units operate efficiently with low-temperature heat sources, such as heat pumps and condensing boilers, making them well-integrated into modern, energy-efficient heating systems. Low thermal inertia allows heat or cool to be supplied only as needed, significantly reducing energy consumption and avoiding overheating of rooms.
EC fans ensure quiet operation and maximum efficiency, achieving up to 4 times greater convection efficiency compared to natural convection solutions. This allows for quick and even distribution of heat or cool throughout the room volume.
FCH units are equipped with durable stainless steel casings, designed to withstand pedestrian loads and support the weight of several adults. Double-sided aesthetic grilles made of aluminum or oak wood allow the solution to be easily matched with floor coverings and interior design concepts, maintaining minimal visual impact on the space.
- Stainless steel casing
- Heat exchanger holder
- Cover for hydraulic connections
- Casing reinforcement elements
- Air deflection element
- Condensate tray
- Copper-aluminum heat exchanger
- Air vent
- Heat exchanger protection-fixing elements
- Fan with EC motor
- Air filter
- Fan vibration isolation pads
- Control unit (ordered separately)
- Protective-decorative grilles (ordered separately)
- Adjustable height legs
- Sound-insulating leg pads
- Casing floor mounting elements
- Sound-insulating gaskets
- Pipe sealing-protection elements
- Cable sealing-protection elements
- Blanks for unused openings
- Anodized aluminum frame; color matches the grille color
Mounting hardware
Installation manual
5-layer, 2-part corrugated cardboard box, also used as a protective cover for the device during construction work

Room Thermostat TW24
For maintaining the set room temperature. Controls actuator A24NC
Dimensions 88 x 88 mm
Weekly temperature schedule programming
Operating temperature 5 - 35°C
Operating voltage - 24V DC, current - 3A
E power - 1.5W
Thermostatic Valve (Straight) TVSP15
For regulating the energy carrier flow. Controlled by actuator A24NC
Operating temperature -10℃ - 120℃
Thread 1/2″
Pressure class - PN10
Kvs - 2.00
Body - nickel-plated bronze
Return Flow Limiter (Straight) LS15
For opening, closing, and setting the maximum flow of the energy carrier
Operating temperature -10℃ - 120℃
Thread 1/2″
Pressure class - PN10
Kvs - 2.00
Body - nickel-plated bronze
Return Flow Limiter (Angled) LA15
For opening, closing, and setting the maximum flow of the energy carrier
Operating temperature -10℃ - 120℃
Thread 1/2″
Pressure class - PN10
Kvs - 2.00
Body - nickel-plated bronze
Actuator for Thermostatic Valve A24NC
For opening/closing the thermostatic valve. Controlled by room thermostat TW24
Operating voltage - 24V DC
E power - 2.5W
Protection class - IP54
Connection thread - M30 x 1.5mm
Casing material PC/ABS
Control unit CB60
For connecting and powering fans, A24NC actuators, and TW24 room thermostat
24V DC power supply
Power - 20W
Current - 0.84A
E connection terminals
Stainless steel casing
CONVECTOR ORDER CODE
| MODEL | LENGTH, cm | WIDTH, cm | HEIGHT, cm | EXAMPLE |
| FCH2 | 200 | 32 | 14 | FCH2 200 |
| FCH4 | 200 | 32 | 14 | FCH4 200 |
GRILLE ORDER CODE
| MODEL | LENGTH, cm | WIDTH, cm | MATERIAL | EXAMPLE |
| GR | 200 | 32 | ALS | GR 200-32-ALS |
| GR-L | 200 | 32 | ALS | GR-L 200-32-ALS |
| GR – roll-up grilles | ALS – aluminum grilles, silver color | |
| GR-L – linear grilles | AL10 – aluminum grilles, brown color | |
| AL50 – aluminum grilles, black color | ||
| OAK – oak grilles | ||
ACCESSORY ORDER CODES
ORDER
| MODEL | CODE |
| Straight return flow limiter | LS15 |
| Return flow limiter angular | LA15 |
| Straight thermostatic valve | TVSP15 |
| Axial thermostatic valve | TVA15 |
| Elektroterminė pavara 24V | A24NC |
| Control unit | CB60 |
| Room thermostat | TW24 |
ROLL-UP ALUMINUM GRILLES GR
SILVER (ALS)
BROWN (AL10)
BLACK (AL50)
LINEAR ALUMINUM GRILLES GR-L
SILVER (ALS)
BROWN (AL10)
BLACK (AL50)
ROLL-UP WOODEN GRILLES GR
OAK (OAK)